The whole cabinet is composed of high-power charging modules in parallel, easy to install and maintain
AC Input voltage (V) |
380±10% (45-65Hz) three-phase five-wire |
Rated output power (kW) |
300 |
Output voltage (V DC) |
200-750 |
Max. Output current of single gun (A) |
250 |
Max. Output current of double-gun (A) |
500 |
Power factor |
≥0.95 |
Efficiency |
≥95% |
THDi |
≤5% |
Output voltage error |
±0.5% |
Output current error |
≤1%(≥30A) |
Voltage regulation accuracy |
≤0.5% (When load current changes from 0% to 100%) |
Steady current accuracy |
≤1% (When load current changes from 10% to 100%) |
Ripple peak factor |
≤1% (When load current changes from 0% to 100%; when load voltage changes from 90% to 110%) |
Current - Unbalance |
≤3% |
Starting impulse current |
≤110% of input current |
Charging mode |
Constant current, constant voltage, constant power |
|
Voltage, current, capacity |
Display |
HMI |
Communication |
RS485/CAN/Ethernet (optional) |
Data collection speed (s) |
≤1 |
Metering |
DC meter |
Protection level |
IP54 |
Altitude (m) |
≤2000 |
Ambient temperature (℃) |
-20 to 50 |
Humidity |
≤95% |
Storage temperature (℃) |
-30 to 70 |
Dimensions (W×D×H, mm) |
800×1000×2200 |
Weight (kg) |
400 |
Standards |
GB/T 18487.1-2015, GB/T 18487.2-2017, GB/T 20234.1-2015, GB/T 20234.3-2015, GB/T 27930-2015 |
Protections |
Overvoltage, undervoltage, overcurrent, undercurrent, short circuit, output reverse connection, automatic shutdown,anti-reverse connection protection module, manual emergency stop button, independent overvoltage protection device, etc. |